click:Release Date:2023/6/10
Under the influence of various factors during the operation of the tarpaulin stripper, electric leakage may occur, which may affect the operation of the equipment. Therefore, it is necessary to master certain treatment methods. Now let's look at the correct treatment of electric leakage of the tarpaulin stripper
Tarpaulin buckle machine
1. The tarpaulin buckle machine is equipped with a circuit device. If there is a leakage, the circuit connecting the machine head to the bottom plate can be checked for good contact
2. For safety reasons, the tarpaulin buckle machine should not be placed on damp ground. However, if the machine is placed on damp ground, operators should wear rubber soled shoes for operation
3. Also, if there is leakage, you can also pay attention to a grounding copper strip from the rack to the upper balance plate and check if the copper strip is properly pressed
4. If the machine is using a three-phase four wire power supply, in case of leakage, it is necessary to check whether the zero wire of the tarpaulin buckle machine is properly connected